Technical Bulletins

Up to date product information, solutions and best practices are addressed in our technical bulletins. Need a solution – call us at 1 800 887 4708

 

EmailFacebookTwitterLinkedInShare

STRUCTA V TRUSS WALLS & CEILINGS (RIB LATH) IS NEW & IMPROVED

Structa Wire Corp., is a leader in developing innovative solutions for stucco reinforcing. An IMPROVED version of  V Truss Walls & Ceilings (an Code approved alternative to 3.4 Rib lath), is now available.  The product has been enhanced to provide for high performance for both One Coat and Three Coat plaster soffits.   The product  …

READ MORE

Structa Wire is included in SpecLink-E

  Structa Wire Corp., is a leader in developing innovative solutions for stucco reinforcing. The industry’s specifications provider BSD SpecLink-E, will promote Structa Wire  products to architects, engineers, and project managers. The partnership will enable Structa Wire to deliver reliable information about Structa products to specifiers at the moment they need it.   SpecLink-E enables designers to  …

READ MORE

Moisture Intrusion into Stucco Walls

Moisture intrusion into building walls in wetter climates has become a growing concern. The results can be damage to framing components, either wood or steel, and potential of mold forming in the walls or the batt insulation. Many of these buildings have stucco cladding, and stucco has been scrutinized as to its contribution to the  …

READ MORE

3 Coat Stucco -Wall Assembly for Continuous Insulation

The new energy code regulations means increased use of Continuous Insulation over framed wall construction. In steel stud construction especially, the transference of heat and cold through the stud itself, known as thermal bridging, can minimize or negate the desired R value of the cavity insulation. Utilizing foam insulation on the outboard side of the  …

READ MORE

Mega Lath is Versatile and Helps Stucco Walls Achieve Higher LEED Ratings

Issued: March 2016   Steel framed buildings have many advantages, but the major negative is the thermal bridging losses through the steel webs. More stringent energy codes are forcing architects and designers to devise new designs to not only meet present requirements, but to strive further to achieve higher LEEDS ratings, and ultimately strive toward  …

READ MORE

Recommended Fasteners for Structa Lath

Issued: March 2016   1. Wood framing – vertical.                          Nails – 0.1205-inch (11 ga ) diameter, 7/16-inch head diameter, barbed galvanized roofing nails. Minimum length – 1-inch. Screws – 0.120-inch shank diameter, 7/16-inch diameter pan or wafer head, galvanized sharp point wood screws Staples – 16 ga diameter, crowns not less than ¾-inch, galvanized.  …

READ MORE

Risk of Corrosion in Wall Cladding Systems

May 4, 2010 Revised September 3, 2010 Revised August 2015   Corrosion of steel laths in stucco plasters is an ongoing concern. All of our lath and corner reinforcement products are hot galvanized to provide corrosion resistance. However it must be noted that the galvanization requirement per ASTM Standards provides protection during storage, before use,  …

READ MORE

Wire Tying along Horizontal Side Laps

Issued: July 2015   Section 7.8.1 of ASTM C1063 states that side laps of metal plaster bases must be wire tied between supports at intervals not more than 9 inches. Historically, Structa Wire laths have not been wire tied at side laps. Over many years, the resulting stucco claddings have not shown or experienced failures  …

READ MORE

Recommended Fastening VTruss Walls & Ceiling Lath

Issued: July 2015   VTRUSS Walls & Ceilings or Structa Rib Lath is designed for superior performance of stucco on overhead surfaces. To determine best installation practices Structa Wire has conducted tests on direct attachment of soffit laths to wood framing, without sheathing. Two lath types were evaluated – Structa V-Truss Wall & Ceilings, and  …

READ MORE

Galvanizing Lath – Standards & Specifications

Issued: June 2015   LATH  GALVANIZING  SPECIFICATIONS IN BUILDING CODES   Corrosion protection of metals including lathing for  cement  plaster  (stucco)  is  governed  by  building codes. Corrosion protection is prescribed as galvanization. The  following  outlines  the  standards  and requirements for galvanization that are now in effect in the US states that have adopted the IBC and IRC codes:  In Table 2507.2 titled “Lath, Plastering Materials and Accessories”, the International Building Code (IBC) cites ASTM C847 – Metal Lath; ASTM C933 – Welded Wire lath; and ASTM C1032 – Woven wire plaster base. In Table 2511.1 titled  …

READ MORE